← All publications

conference · 2025 · Published (e-poster)

Assessment of AI Performance in Detecting Breast Lesions on MRI: A Retrospective Study in a Chinese Cohort

Siming Bayer · Adarsh Bhandary Panambur · Xiaoyang Du · Robert Grimm · Heinrich von Busch · Andreas Maier · Juan Huang · Su Lui

01 / SUMMARY

What this paper does

A breast MRI AI prototype developed in Europe was evaluated retrospectively on an external Chinese cohort — the kind of test that decides whether a model generalizes or merely fits its development population. 200 cases were sampled from a 4,000-patient West China Hospital breast MRI cohort acquired between November 2017 and August 2023, using multi-sequence 3T MRI with expert lesion annotations. Case-level sensitivity was 0.906, with a median of 0 false positives per case, an average of 0.635, and a maximum of 7 in a single case. This work came out of a guest research stay at the hospital.

02 / METHOD

How

Retrospective sampling of 200 cases from a 4,000-patient breast MRI cohort, multi-sequence 3T acquisition with expert lesion annotations, evaluated at case level for sensitivity and per-case false-positive count.

03 / FINDINGS

Reported results

  • Case-level sensitivity 0.906.
  • False positives: median 0 per case, average 0.635 per case, maximum 7 in a single case.
  • 200 cases sampled from a 4,000-patient West China Hospital cohort, November 2017 to August 2023.
04 / WHY IT MATTERS

Relevance

For breast MRI to be usable at volume, sensitivity alone is not the constraint — the false-positive burden per case is what determines whether radiologists can work with the output.

05 / LIMITATION

What it does not show

Retrospective, single external centre, 200 sampled cases, published as a conference e-poster. Specificity was not reported in the exhibit.

06 / REFERENCE

Citation

S. Bayer, A. Bhandary Panambur, X. Du, R. Grimm, H. von Busch, A. Maier, J. Huang, S. Lui. Assessment of AI Performance in Detecting Breast Lesions on MRI: A Retrospective Study in a Chinese Cohort. ECR 2025, EPOS C-21110. doi:10.26044/ecr2025/C-21110

View original abstract

Retrospective external evaluation of a breast MRI AI research prototype on multi-sequence 3T examinations from West China Hospital, with expert lesion annotations, reporting case-level sensitivity and per-case false-positive burden.